Skip to main content

Table 4 Recurrence rate 12 months after ablation according to monitoring method

From: Validation of seven risk scores in an independent cohort: the challenge of predicting recurrence after atrial fibrillation ablation

 

A. Only occasional 12-lead ECGs and history (37.7%)

B. Holter-ECG (46.0%)

C. Device interrogation (16.3%)

p value

Recurrence rate after 12 months (%)

31.1

39.5

45.6

p < 0.05 between A and B, as well as A and C; p = 0.206 between B and C